EasyManuals Logo
Home>Danfoss>Controller>AK-CC 550A

Danfoss AK-CC 550A User Manual

Danfoss AK-CC 550A
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
AK-CC 550A Manual RS8FS402 © Danfoss 2016-03 27
Case Room
Defrost stop on
time
Defrost stop
on S5
Defrost stop on
time
Defrost stop
on S5
Preset settings (o62) 1 2 3 4 5 6
Temperature (SP)
2°C -2°C -28°C 4°C 0°C -22°C
Max. temp. setting (r02)
6°C 4°C -22°C 8°C 5°C -20°C
Min. temp. setting (r03)
0°C -4°C -30°C 0°C -2°C -24°C
Sensor signal for thermostat. S4% (r15)
100% 0%
Alarm limit high (A13)
8°C 6°C -15°C 10°C 8°C -15°C
Alarm limit low (A14)
-5°C -5°C -30°C 0°C 0°C -30°C
Sensor signal for alarm funct.S4% (A36)
0% 100% 0%
Interval between defrost (d03)
6 h 6h 12h 8h 8h 6h
Defrost sensor: 0=time, 1=S5, 2=S4 (d10)
0 1 1 0 1 1
DI1 cong. (o02)
Appliance cleaning (=10) Door function (=2)
Sensor signal for display view S4% (017)
0%
Note: For applications 9 and 10 the sensor weighting for the S3/S4 sensors is not used for the thermostat, alarm thermostat and display readings as the
sensor uses are predened.
Auxiliary schedule for settings (quick-setup)

Other manuals for Danfoss AK-CC 550A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss AK-CC 550A and is the answer not in the manual?

Danfoss AK-CC 550A Specifications

General IconGeneral
BrandDanfoss
ModelAK-CC 550A
CategoryController
LanguageEnglish

Related product manuals