Instructions ECL Comfort 210 / 310, communication description
Summer time rules
The rules for summer time change are the EU rules for central
Europe. If the automatic summer time is enabled, the hour in
which the clock is set forward is not a valid time. If the time is
changed from 02:00 to 03:00, the time between 02:00 and
03:00 cannot be valid. Consequently, it is therefore not
possible to change the time to e.g. 02:15 on the day where
the summer time change takes place. By disabling automatic
summer time it is possible to overcome this problem but
remember to enable it again!
When the clock is set back to normal time in autumn, the time
between 02:00 and 03:00 will exist twice. The controller will
therefore automatically assume that any time adjustment in
that interval is after the changeover, i.e. that the summer time
has ended.
Summer time starts on the last Sunday in March and ends on
the last Sunday in October.
Automatic summer time is enabled by writing 1 to address
10198 and disabled by writing 0 to the same address.
6.7 Rules for schedule adjustment
The ECL Comfort divides the schedules into 7 days
(1–7), each day consisting of 48 periods lasting 30 minutes.
1. The periods must be entered in chronological order, i.e.
P1 ... P2 ... P3.
2. Start and stop values must be in the range 0, 30, 100, 130,
200, 230 …, 2300, 2330, 2400.
3. Start values must be before stop values if the period is
active.
4. When a stop period is written to zero, the period is
automatically deleted as well as any previous periods
.
5. When a start period is written different from zero, a period
is automatically added.
Table 6-5: Address range circuit 1
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
P1 Start 1 3110 3120 3130 3140 3150 3160 3170
Stop 1 3111 3121 3131 3141 3151 3161 3171
P2 Start 2 3112 3122 3132 3142 3152 3162 3172
Stop 2 3113 3123 3133 3143 3153 3163 3173
P3 Start 3 3114 3124 3134 3144 3154 3164 3174
Stop 3 3115 3125 3135 3145 3155 3165 3175
Danfoss District Energy VI.LG.V3.02 DEN-SMT/DK
14

Other manuals for Danfoss ECL Comfort A368

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ECL Comfort A368 and is the answer not in the manual?

Danfoss ECL Comfort A368 Specifications

General IconGeneral
BrandDanfoss
ModelECL Comfort A368
CategoryController
LanguageEnglish

Related product manuals