6 Temperature, PT100, windings
7 GND, Temperature, PT100, windings (corresponds to pin1 PT100)
8 GND, Temperature, PT100, windings (corresponds to pin2 PT100)
9 GND, Temperature, PT100, windings (corresponds to pin3 PT100)
10 GND, Temperature, PT100, windings (corresponds to pin4 PT100)
11 GND, Temperature, PT100, windings (corresponds to pin5 PT100)
12 GND, Temperature, PT100, windings (corresponds to pin6 PT100)
The shielded measurement cable shield can be connected to a low voltage grounding connection
point. See Figure below, and Chapter
Grounding connection
s for more information.
Grounding connections
The grounding points on the frame of the electric machine are for safety
grounding, and signal cables and power cable
shields have their own grounding points.
Figure 40. The machine enclosure grounding point, safety grounding