General Specifications
Pulse/encoder inputs:
Programmable pulse/encoder inputs ............................................................................................. 2/1
Terminal number pulse/encoder ........................................................................ 29, 33
1)
/ 18, 32, 33
2)
Max. frequency at terminal 18, 29, 32, 33 .................................................... 110 kHz (Push-pull driven)
Max. frequency at terminal 18, 29, 32, 33 ........................................................... 5 kHz (open collector)
Min. frequency at terminal 18, 29, 32, 33 .................................................................................... 4 Hz
Voltage level ............................................................................................. see section on digital input
Maximum voltage on input ................................................................................................... 28 V DC
Input resistance, R
i
...................................................................................................... approx. 4 k
Pulse input accuracy (0.1 - 1 kHz) .......................................................... Max. error: 0.1% of full scale
Encoder input accuracy (1 - 110 kHz) .................................................... Max. error: 0 .05 % of full scale
The pulse and encoder inputs (terminals 18, 29, 32, 33) are galvanically isolated from the
supply voltage (PELV) and other high-vo ltage terminals.
1) Pulse inputs are 29 and 33
2) Encoder inputs: 18 = Z , 32 = A, and 33 = B
Digital output
Programmable digital/pulse outputs ................................................................................................2
Terminal number ................................................................................................................. 27, 29
1)
Voltage level at digital/frequency output ................................................................................. 0 - 24 V
Max. output current (sink or source) ........................................................................................ 40 mA
Max. load at digital/frequency output .......................................................................................... 1 k
Max. load at digital/frequency output ......................................................................................... 10 nF
Minimum output frequency at frequency output ........................................................................... 0 H z
Maximum output frequency at frequency output ....................................................................... 32 kHz
Accuracy on frequency output ................................................................. Max. error: 0.1% of full scale
Resolution on frequency output ................................................................................................ 12 bit
1) Terminal 27 and 29 can also be programmed as intput.
The digital output is galvanical ly isolated from th e supply voltage (PELV) and other high-voltage terminals.
Analog output:
Number of programmable a nalog outputs ......................................................................................... 1
Terminal number ......................................................................................................................... 42
Current range at analog output ....................................................................................... 0/4 - 20 mA
Max. load to common at analog output ..................................................................................... 500
Accuracy on analog output ..................................................................... Max. error: 0.5% of full scale
Resolution on analog o utput .................................................................................................... 12 bit
The analog output is galvonically isolated from the supply voltage (PEL V) and other high-voltage terminals.
Control card, 24 V DC output:
Terminal number ................................................................................................................... 12, 13
Max. load ...................................................................................... FC 301: 130 mA / FC 302: 200 mA
The 24 V DC supply is galv onically isolated from the supply voltage (PELV), but has the same
potential as the analog and digital inputs and outputs.
Control card, 10 V DC output:
Terminal number ......................................................................................................................... 50
Output voltage ............................................................................................................ 10.5 V ±0.5 V
Max. load ............................................................................................................................. 15 mA
The 10 V DC supply is g a lvoni cally isolated from the supply voltage (PELV) and othe r high-voltage terminals.
63
MG.33.A4.22 - VLT is a registered Danfoss trademark

Other manuals for Danfoss FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss FC 302 and is the answer not in the manual?

Danfoss FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelFC 302
CategoryMedia Converter
LanguageEnglish

Related product manuals