EasyManuals Logo
Home>Danfoss>Control Unit>PVG 32

Danfoss PVG 32 Service Manual

Danfoss PVG 32
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
PVG 32 sectional drawing
1. Pressure relief valve
2. Pressure reduction valve for pilot oil supply
3. Pressure gauge connection
4. Plug, open centre
5. Orifice, closed centre
6. Pressure adjustment spool
7. Plug, closed centre
8. LS connection
9. LS signal
10. Shuttle valve
11. Main spool
12. LS pressure limiting valve
13. Shock and suction valve, PVLP
14. Pressure compensator
15. LS connection, port A
16. LS connection, port B
17. Suction valve, PVLA
18. Load drop check valve
19. Pilot oil supply for PVE
20. Max. oil flow adjustment screws for
ports A and B
PVP
PVB
PVB
PVPC plug for external pilot oil supply
PVPC with check valve for open center PVP
PVPC, with check valve, is used in systems where it is necessary to operate the PVG 32 valve by means of
the electrical remote control without pump flow. When the external solenoid valve is opened, oil from
Service Manual
PVG 32 Proportional Valve Group
Operation
©
Danfoss | February 2017 11039167 | AX00000031en-US0301 | 9

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals