TP9000
6
Wiring
NOTE:
The TP9000 does not have voltage free contacts, therefore it is NOT
suitable for connection to extra low voltage equipment (i.e. > 50
Volts).
Remote Sensor to be wired with 1mm 2 core double insulated cable
only. Cable length should not exceed 50 metres. Sensor cable should
NOT be run parallel to mains cable.
Remote sensor inputs
The TP9000 incorporates an input which can be used to connect one
of the following:
1) remote room temperature sensor
2) limit sensor, for example, fl oor temperature sensor (sold as
accessory).
3) window contacts, card reader contacts, outdoor sensor (sold as
accessory) or teleswitch contacts.
See Installer Advanced Programming Options for set-up instructions.