26 MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Mains supply 3 x 440/460/500 V
Technical data
Acc. to international VDE and UL/CSA requirements VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
Constant torque (CT):
Output current I
VLT,N
[A] 2.6 3.4 4.8 8.2 11.1 14.5 21.7 27.9 41.4 54.0 65.0
I
VLT,MAX
[A] (60s) 3.4 5.5 7.7 13.1 17.6 23.2 34.7 44.6 67.2 86.4 104.0
Output S
VLT,N
[kVA] 2.3 2.9 4.1 7.1 9.6 12.6 18.8 24.2 36.0 46.8 56.3
S
VLT,MAX
[kVA] (60s) 2.9 4.7 6.7 11.3 15.2 20.1 30.1 38.6 58.2 7.8 90.1
Typical shaft output P
VLT,N
[kW] 1.1 1.5 2.2 4.0 5.5 7.5 11.0 15.0 22.0 30.0 37.0
Quadratic torque (VT):
Output current I
VLT,N
[A] 2.6 3.4 4.8 8.2 11.1 21.7 27.9 41.4 54.0 65.0 78.0
Output S
VLT,N
[kVA] 1.6 2.9 4.1 7.1 9.6 18.8 24.2 35.9 46.8 56.3 67.5
Typical shaft output P
VLT,N
[kW] 1.1 1.5 2.2 4.0 5.5 11.0 15.0 22.0 30.0 37.0 45.0
Max. cable cross-section [mm
2
] 2.5 2.5 2.5 2.5 2.5 16.0 16.0 16.0 35.0 35.0 50.0
Max. motor cable length [m] 300, with screened cables: 150 m (3011-3052 in VT: 150 m and 40 m)
Output voltage U
M
[%] 0-100, of mains voltage
Output frequency f
M
[Hz] 0-120 eller 0-500, programmable
Rated motor voltage U
M,N
[V] 440/460/500
Rated motor frequency f
M,N
[Hz] 50/60/87/100
Thermal protection during operation Integrated thermal motor protection (electronic); thermistor to DIN 44081
Switching on output Unlimited (frequent switching on output may result in fault message)
Ramp times [s] 0.1 – 3600
VLT
type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
Max. const. load. [A] 2.6 3.4 4.8 8.2 11.1 12.6 20.1 26.8 37.3 50.2 61.3
input current quadratic load [A] 2.6 3.4 4.8 8.2 11.1 19.6 26.0 34.8 48.6 60.3 72.0
Max. cable cross-section [mm
2
] 2.5 2.5 2.5 2.5 2.5 16.0 16.0 16.0 35.0 35.0 50.0
Max. pre-fuses [A] 16.0 16.0 16.0 25.0 25.0 30.0 40.0 50.0 60.0 100.0
1)
125.0
1)
Supply voltage (VDE 0160) [V] 3 x 440/460/500 ±10% (VDE 0160)
Supply frequency [Hz] 50/60
Power factor / cos. ϕ
1
0.9/1.0
Efficiency 0.96 at 100% load
Switching on input times/min. 2
VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
Weight (kg)
IP 007.47.47.41214 - ---- -
IP 20 - - - - - 25 26 31 49 54 54
IP 218.08.08.01315 - ---- -
IP 54 11 11 11 14 15 34 37 48 63 69 69
Power loss at max. load
CT [W] 60 100 130 160 200 174 287 580 958 1125 1467
VT [W] 60 100 130 160 200 281 369 880 1133 1440 1888
Enclosure
VLT type 3002-08: IP 00 / IP 21 / IP 54 VLT type 3011-52: IP 20 /IP54
VLT type 3042-52: IP 20 / IP 54
Vibration test [g] 0.7
Relative humidity [%] VDE 0160 5.2.1.2.
[°C] -10→ +40 -10→ +45/40(CT/VT)
Ambient temperature at full load
2)
at full load
2)
(to VDE 0160) [°C] -25→ +65/70 -25→ +65/70
in storage/transport in storage/transport
Frequency converter protection Protection against earthing and short-circuiting
EMC standards
Emission EN 55011, EN 55014
(See section “EMC test results”)
Immunity EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5, VDE 0160, ENV 50140, ENV 50141
1) Semi-conductor fuses.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the specifications.