41MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Mechanical installation
VLT
®
type 3100-3150 3200-3250
A [mm] 79 102
B [mm] 153 178
a [mm] 23 10
b [mm] 191 287
Base for mounting console and IP 54, RFI module:
VLT
®
type 3100-3150 3200-3250
A [mm] 76 100
B [mm] 151 176
a [mm] 23 10
b [mm] 191 287
Base:
Base seen from side:
previous versions of VLT
®
3100-3250
units, but never use the previous base
design for the VLT
®
units with the remov-
able base plate.
The bases for VLT
®
and options have been
updated to match VLT
®
3100-3250 with
the removable plate in the bottom. Note
that the ventilation slots have been re-
placed with two apertures in the sides.
When a base is also used for the mounting
console and RFI in IP 54 enclosure,
remember to match up the ventilation
apertures.
The new base design can be used with
VLT
®
type 3100-3150 3200-3250
A [mm] 127 127
B [mm] 495 495
C [mm] 361 495
D [mm] 4 x 12.7 4 x 12.7
b [mm] 445 445
c [mm] 310 445
The drawing shows the base and its
dimensions.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Other manuals for Danfoss VLT 3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 3000 Series and is the answer not in the manual?

Danfoss VLT 3000 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 3000 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals