Compact, AC line supply 3 x 200-240 V
According to international requirements VLT type 5032 5042 5052
Normal overload torque (110 %):
Output current
I
VLT,N
[A] (200-230 V)
115 143 170
I
VLT, MAX
(60 s) [A] (200-230 V)
127 158 187
I
VLT,N
[A] (231-240 V)
104 130 154
I
VLT, MAX
(60 s) [A] (231-240 V)
115 143 170
Output
S
VLT,N
[kVA] (208 V)
41 52 61
S
VLT,N
[kVA] (230 V)
46 57 68
S
VLT,N
[kVA] (240 V)
43 54 64
Typical shaft output [HP] (208 V) 40 50 60
Typical shaft output [kW] (230 V) 30 37 45
High overload torque (160 %):
Output current
I
VLT,N
[A] (200-230 V)
88 115 143
I
VLT, MAX
[A] (200-230 V)
132 173 215
I
VLT,N
[A] (231-240 V)
80 104 130
I
VLT, MAX
[A] (231-240 V)
120 285 195
Output
S
VLT,N
[kVA] (208 V)
32 41 52
S
VLT,N
[kVA] (230 V)
35 46 57
S
VLT,N
[kVA] (240 V)
33 43 54
Typical shaft output [HP] (208 V) 30 40 50
[kW] (230 V) 22 30 37
Max. cable cross-section to motor
and load sharing
[mm
2
]
4,6
[AWG]
2,4,6
120
300 mcm
Max. cable cross-section to brake
[mm
2
]
4,6
[AWG]
2,4,6
25
4
Normal overload torque (110 %):
Rated input current
I
L,N
[A] (230 V)
101.3 126.6 149.9
Normal overload torque (150 %):
Rated input current
I
L,N
[A] (230 V)
77,9 101,3 126,6
Max. cable cross-section
power supply
[mm
2
]
4,6
[AWG]
2,4,6
120
300 mcm
Min. cable cross-section to motor,
power
supply, brake and load sharing
[mm
2
]
4,6
[AWG]
2,4,6
6
8
Max. pre-fuses (line) [-]/UL
[A]
1
150/15
0
200/200 250/250
Efficiency
3
0,96-0,97
Power loss
Normal overload [W]
1089 1361 1612
High overload [W] 838 1089 1361
Weight
IP 00 [kg]
101 101 101
Weight IP 20 Nema1 [kg] 101 101 101
Weight
IP 54 Nema12 [kg] 104 104 104
Enclosure IP 00 / Nema 1 (IP 20) / IP 54
1. For type of fuse, see section Fuses.
2. American Wire Gauge.
3. Measured using 100 ft [30 m] shielded motor cables at rated load and rated frequency.
4. Max. cable cross-section is the maximum possible cable cross-section allowed to be fitted on the terminals. Min. cable cross-section
is the minimum allowed cross-section. Always comply with national and local regulations on min. cable cross-section.
5. Weight without shipping container.
6. Connection stud: M8 Brake: M6.
VLT
®
5000 Series
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark. 15
Technical data

Table of Contents

Other manuals for Danfoss VLT 5032

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5032 and is the answer not in the manual?

Danfoss VLT 5032 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5032
CategoryDC Drives
LanguageEnglish

Related product manuals