Local and remote control
The adjustable frequency drive can be operated man-
ually or remotely. The following is a list of the functions/
commands given via the control panel, the digital in-
puts or the serial communication port in the two situa-
tions (modes).
If parameter 002 is set to Local [1]:
On the LCP, the following keys can be used for local control:
Key: Parameter: Data value:
[STOP] 014 [1] Enable
[JOG] 015 [1] Enable
[RESET] 017 [1] Enable
[FWD/REV] 016 [1] Enable
Set parameter 013 for LCP control and open loop [1] or LCP control as parameter 100 [3]:
1. Local reference is set in parameter 003; can be changed via the "+/-" keys.
2. Reversing can be effected by means of the [FWD/REV] key.
Set parameter 013 for LCP digital control and open loop [2] or LCP digital control as parameter 100 [4]:
For the above parameter setting, it is now possible to
control the adjustable frequency drive as follows:
Digital inputs:
1. Local reference set in parameter 003 can be
changed via the "+/-" keys.
2. Reset via digital terminal 16, 17, 29, 32 or 33.
3. Stop inverse via digital terminal 16, 17, 27,
29, 32 or 33.
4. Choice of Setup, lsb via digital terminal 16,
29 or 32.
5. Choice of Setup, msb via digital terminal 17,
29 or 33.
6. Ramp 2 via digital terminal 16, 17, 29, 32 or
33.
7. Quick-stop via digital terminal 27.
8. DC braking via digital terminal 27.
9. Reset and motor coasting stop via digital ter-
minal 27.
10. Motor coasting stop via digital terminal 27.
11. Reversing via digital terminal 19.
12. Choice of Setup, msb/speed up via digital
terminal 32.
13. Choice of Setup, lsb/speed down via digital
terminal 33.
The serial communication port:
1. Ramp 2
2. Reset
3. Choice of Setup, lsb
4. Choice of Setup, msb
5. Relay 01
6. Relay 04
If parameter 002 is set to Remote control [0]:
Key: Parameter: Data value:
[STOP] 014 [1]
[JOG] 015 [1]
[RESET] 017 [1]
VLT
®
5000 Series
188 MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.

Table of Contents

Other manuals for Danfoss VLT 5032

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5032 and is the answer not in the manual?

Danfoss VLT 5032 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5032
CategoryDC Drives
LanguageEnglish

Related product manuals