Read-out state I:
This read-out state is standard after starting up or after
initialisation.
50.0 Hz
FREQUENCY
MOTOR IS RUNNING
Line 2 gives the data value of an operating variable
with related unit, and line 1 provides a text which ex-
plains line 2, cf. table. In the example, Frequency has
been selected as variable via parameter 009. During
normal operation another variable can immediately be
read out by using the [+/-] keys.
Read-out state II:
Switching between read-out states I and II is effected
by pressing the [DISPLAY / STATUS] key.
MOTOR IS RUNNING
50.0 Hz
24.3% 30.2% 13.8A
In this state, data values for four operating values are
shown at the same time, giving the related unit, cf. ta-
ble. In the example, Reference, Torque, Current and
Frequency are selected as variables in the first and
second line.
Read-out state III:
This read-out state can be held as long as the [DIS-
PLAY/STATUS] key is pressed. When the key is re-
leased, the system switches back to Read-out state II,
unless the key is pressed for less that approx. 1 sec.,
in which case the system always reverts to Read-out
state I.
50.0 Hz
SETUP
1
MOTOR IS RUNNING
REF% TORQUE CURR A
This is where parameter names and units for operating
variables in the first and second line are given - oper-
ating variable 2 remains unchanged.
Display state IV:
This display state can be produced during operation if
another setup is to be changed without stopping the
adjustable frequency drive. This function is activated
in parameter 005, Programming Setup.
MOTOR IS RUNNING
50.0 Hz
24.3% 30.2% 13.8A
The selected programming setup number will flash to
the right of the active setup.
Parameter Setup
The VLT 5000 Series can be used for practically all
assignments, which is why the number of parameters
is quite large. Also, this series offers a choice between
two programming modes - a Menu mode and a Quick
menu mode.
The former provides access to all parameters. The lat-
ter takes the user through a few parameters which
make it possible in most cases to start operating the
adjustable frequency drive.
Regardless of the mode of programming, a change of
a parameter will take effect and be visible both in the
Menu mode and in the Quick menu mode.
Structure for the Quick menu mode versus the
Menu mode
In addition to having a name, each parameter is linked
up with a number which is the same regardless of the
programming mode. In the Menu mode, the parame-
ters are divided into groups, with the first digit of the
parameter number (from the left) indicating the group
number of the parameter in question.
The quick menu takes the user through a
number of parameters that may be enough to
get the motor to run nearly optimally, if the
factory setting for the other parameters takes
the desired control functions into account, as
well as the configuration of signal inputs/out-
puts (control terminals).
VLT
®
5000 Series
74 MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.

Table of Contents

Other manuals for Danfoss VLT 5032

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5032 and is the answer not in the manual?

Danfoss VLT 5032 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5032
CategoryDC Drives
LanguageEnglish

Related product manuals