4.3.3 Assembly of F Frame Sections
Procedure to attach F frame drive and filter sections together
1. Position filter and drive sections in proximity to one another. The filter section will attach to the left side of the drive section.
2. Open the rectifier section door and remove the cover shielding the bus bars.
130BB435.10
Cover shielding bus bars
3. Apply included gasket to indicated surface on cabinet.