5.1.3 Q1 My Personal Menu
Parameters defined by the user can be stored in Q1 My Personal Menu.
Select
My Personal Menu
to display only the parameters, which have been pre-selected and programmed as personal parameters. For example, a pump
or equipment OEM may have pre-programmed these to be in My Personal Menu during factory commissioning to make on-site commissioning / fine tuning
simpler. These parameters are selected in par. 0-25
My Personal Menu
. Up to 20 different parameters can be defined in this menu.
Q1 My Personal Menu
20-21 Setpoint 1
20-93 PID Proportional Gain
20-94 PID Integral Time
5.1.4 Q2 Quick Set-up
The parameters in Q2 Quick Set-up are the basic parameters which are always needed to set up the adjustable frequency drive for operation.
Q2 Quick Set-up
Parameter number and name Unit
0-01 Language
1-20 Motor Power kW
1-22 Motor Voltage V
1-23 Motor Frequency Hz
1-24 Motor Current A
1-25 Motor Nominal Speed RPM
3-41 Ramp 1 Ramp-up Time s
3-42 Ramp 1 Ramp-down Time s
4-11 Motor Speed Low Limit RPM
4-13 Motor Speed High Limit RPM
1-29 Automatic Motor Adaptation (AMA)
VLT AQUA High Power Instruction Manual
5 How to program the adjustable frequency
drive
MG.20.P3.22 - VLT
®
is a registered Danfoss trademark
5-3
5