4 Options and Accessories Overview
4.1 Fieldbus Devices
4.1.1 Overview
This chapter describes the fieldbus devices that are available with the drive. Using a fieldbus device reduces system cost, delivers faster
and more efficient communication, and provides an easier user interface.
4.1.2 VLT® PROFIBUS DP-V1 MCA 101
The VLT® PROFIBUS DP-V1 MCA 101 provides:
l Wide compatibility, a high level of availability, support for all major PLC vendors, and compatibility with future versions.
l Fast, efficient communication, transparent installation, advanced diagnosis, and parameterization and auto-configuration of process
data via a GSD file.
l Acyclic parameterization using PROFIBUS DP-V1, PROFIdrive, or Danfoss FC profile state machines.
4.1.3 VLT® PROFINET MCA 120
The VLT® PROFINET MCA 120 combines the highest performance with the highest degree of openness. The option is designed so that
many of the features from the VLT® PROFIBUS MCA 101 can be reused, minimizing user effort to migrate PROFINET and securing the
investment in a PLC program.
l Same PPO types as the VLT® PROFIBUS DP-V1 MCA 101 for easy migration to PROFINET.
l Built-in web server for remote diagnosis and reading out of basic drive parameters.
l Supports MRP.
l Implementation in accordance with Conformance Class B.
4.2 Functional Extensions
4.2.1 Overview
This chapter describes the functional extension options that are available with the drive.
4.2.2 VLT® Encoder Input MCB 102
The VLT® Encoder Input MCB 102 option offers the possibility to connect various types of incremental and absolute encoders. The
connected encoder can be used for closed loop speed control.
4.2.3 VLT® Resolver Option MCB 103
The VLT® Resolver Option MCB 103 option enables connection of a resolver to provide speed feedback from the motor.
l Primary voltage: 2–8 V
rms
.
l Primary frequency: 2.0–15 kHz.
l Primary maximum current: 50 mA rms.
l Secondary input voltage: 4 V
rms
.
l Spring-loaded connection.
4.2.4 VLT® 24 V DC Supply MCB 107
VLT® 24 V DC Supply MCB 107 connects an external DC supply to keep the control compartment and any installed option functioning
during power failure. VLT® 24 V DC Supply MCB 107 also enables full operation of the LCP (including the parameter setting) and all
installed options without connection to mains.
l Input voltage range: 24 V DC +/15% (maximum 37 V for 10 s)
24 | Danfoss A/S © 2024.01 AJ435824192086en-000101 / 130R1295
Design Guide | VLAutomationDrive FC 360

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals