EasyManuals Logo
Home>Danfoss>DC Drives>VLT CANopen MCA 105

Danfoss VLT CANopen MCA 105 User Manual

Danfoss VLT CANopen MCA 105
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
-
-
-
Parameter 5-12 Terminal 27 Digital Input to [2] Coasting Stop, Inverse.
Parameter 5-02 Terminal 29 Mode to [1] Terminal 29 Mode Output.
Parameter 5-31 Terminal 29 Digital Output to [27] Torque limit & stop.
Connect to relay output 1 (XD2.21). Then set parameter 5-40 Function Relay to [32] Mechanical Brake Control.
+24 V DC
P 5-10 [8]
P 5-12 [2]
P 5-02 [1]
P 5-31 [27]
GND
P 5-40 [0] [32]
Relay 1
-
+
e30bu096.10
XD2.19
XD2.18
XD2.17
XD2.16
XD2.15
XD2.14
XD2.13
XD2.12
XD2.11
XD2.10
XD2.23XD2.21 XD2.22
External
24 V DC
Mechanical brake connection
I
max
0.1 Amp
Start
Illustration 73: Wire Configuration for Torque and Stop Limit
AQ262139143212en-000301 / 130R0879136 | Danfoss A/S © 2021.10
Wiring Configuration Examples
VLT® AutomationDrive FC 302
Operating Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals