Table 119: Mains Contactor Switches for VLT
®
AutomationDrive FC 302 Enclosed Drive Models N90K–N250, 525–690 V
N90K
N110
N132
N160
N200
N250
IEC
185 A/1000 V
185 A/1000 V
185 A/1000 V
400 A/1000 V
400 A/1000 V
400 A/1000 V
Eaton P/N
XTCE400M22A
XTCE400M22A
XTCE400M22A
XTCE400M22A
XTCE400M22A
XTCE400M22A
UL
185 A/1000 V
185 A/1000 V
185 A/1000 V
400 A/1000 V
400 A/1000 V
400 A/1000 V
Eaton P/N
XTCE400M22A
XTCE400M22A
XTCE400M22A
XTCE400M22A
XTCE400M22A
XTCE400M22A
Table 120: Mains Contactor Switches for VLT
®
AutomationDrive FC 302 Enclosed Drive Models N315–N560, 525–690 V
N315
N355
N400
N500
N560
IEC
400 A/1000 V
580 A/1000 V
580 A/1000 V
580 A/1000 V
580 A/1000 V
Eaton P/N
XTCE400M22A
XTCE580N22A
XTCE580N22A
XTCE580N22A
XTCE580N22A
UL
400 A/1000 V
580 A/1000 V
580 A/1000 V
580 A/1000 V
580 A/1000 V
Eaton P/N
XTCE400M22A
XTCE580N22A
XTCE580N22A
XTCE580N22A
XTCE580N22A
Table 121: Mains Contactor Switches for VLT
®
AutomationDrive FC 302 Enclosed Drive Models N630–N710, 525–690 V
N630
N710
IEC
580 A/1000 V
820 A/1000 V
Eaton P/N
XTCE580N22A
XTCE820N22A
UL
820 A/1000 V
1000 A/1000 V
Eaton P/N
XTCE820N22A
XTCEC10N22A
10.8.3 Fusible Disconnect Switches
The fusible disconnector switch is an option that safely isolates the drive from the mains with a fuse switch mounted below the
drive module. All units ordered and supplied with a factory-installed fusible disconnect switch have a fuse built in to the switch. The
fuse has been sized to meet 65kA SCCR for the system. The input voltage and power rating of the drive determines the specific class
or gG fuse. The input voltage and power rating are found on the product nameplate.
Table 122: Fusible Disconnect Switches for VLT
®
AutomationDrive FC 302 Enclosed Drive Models N90K–N250, 380–500 V
N90K
N110
N132
N160
N200
N250
IEC
400 A/690 V
400 A/690 V
400 A/690 V
630 A/690 V
630 A/690 V
630 A/690 V
ABB P/N
OS400D30P
OS400D30P
OS400D30P
OS630D30P
OS630D30P
OS630D30P
UL
400 A/600 V
400 A/600 V
400 A/600 V
600 A/600 V
600 A/600 V
800 A/600 V
ABB P/N
OS400J30
OS400J30
OS400J30
OS600J30
OS600J30
OS800L30
Table 123: Fusible Disconnect Switches for VLT
®
AutomationDrive FC 302 Enclosed Drive Models N315–N500, 380–500 V
N315
N355
N400
N450
N500
IEC
1250 A/690 V
1250 A/690 V
1250 A/690 V
1250 A/690 V
1250 A/690 V
ABB P/N
OS1250D30P
OS1250D30P
OS1250D30P
OS1250D30P
OS1250D30P
UL
800 A/600 V
1200 A/600 V
1200 A/600 V
1200 A/600 V
1200 A/600 V
ABB P/N
OS800L30
OS1200L30
OS1200L30
OS1200L30
OS1200L30
AQ262139143212en-000301 / 130R0879182 | Danfoss A/S © 2021.10
Specifications
VLT® AutomationDrive FC 302
Operating Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals