5.1.2 Setting LCP Display Values
The display area is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or
an external 24 V DC supply.
The information displayed on the LCP can be customised
for user application.
Each display readout has a parameter associated
with it.
Options are selected in the quick menu Q3-13
Display Settings.
Display 2 has an alternate larger display option.
The frequency converter status at the bottom line
of the display is generated automatically and is
not selectable.
1.1
2
3
1.3
1.2
130BT831.10
0.0%
Off Remote Stop
1 (1)
0.00 kw0.00 A
0.0Hz
2605kWh
Status
Display Parameter number Default setting
1.1 0-20 Reference %
1.2 0-21 Motor current
1.3 0-22 Power [kW]
2 0-23 Frequency
3 0-24 kWh counter
Illustration 5.2 Display Readouts
5.1.3
Display Menu Keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
130BP045.10
Status
Quick
Menu
Main
Menu
Alarm
Log
Illustration 5.3 Menu Keys
Key Function
Status
Shows operational information.
In Auto mode, press to toggle between
status readout displays.
Press repeatedly to scroll through each
status display.
Press [Status] plus [
] or [
] to adjust the
display brightness.
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu
Allows access to programming parameters for
initial set-up instructions and many detailed
application instructions.
Press to access Q2 Quick Set-up for
sequenced instructions to program the basic
frequency controller set-up.
Follow the sequence of parameters as
presented for the function set-up.
Main Menu
Allows access to all programming parameters.
Press twice to access top-level index.
Press once to return to the last location
accessed.
Press to enter a parameter number for
direct access to that parameter.
Alarm Log
Displays a list of current warnings, the last 10
alarms, and the maintenance log.
For details about the frequency converter
before it entered the alarm mode, select the
alarm number using the navigation keys
and press [OK].
Table 5.6 Function Description Menu Keys
User Interface
Operating Instructions
MG16J202 Danfoss A/S © Rev. 05/2014 All rights reserved. 65
5 5

Table of Contents

Other manuals for Danfoss VLT FC 103

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 103 and is the answer not in the manual?

Danfoss VLT FC 103 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 103
CategoryDC Drives
LanguageEnglish

Related product manuals