VLT
®
FCD Series
ously. During programming, all the information
required for quick, efcient parameter Setup of the
frequency converter is displayed. As a supplement
to the display, the LCP has three indicator lamps for
voltage (ON), warning (WARNING) and alarm
(ALARM). Most of the frequency converters parame-
ter Setups can be changed immediately via the LCP
control panel. See also the section entitled The LCP
control unit in the Design Guide.
Fieldbus protocols
Danfoss frequency converters are able to fulll many
different functions in a process control system. The
frequency converter can be integrated directly in an
overall surveillance system, which will allow detailed
process data to be transferred via serial communica-
tion.
The protocols listed below are based on an RS 485
bus system with a maximum transmission speed of
9600 baud. The following telegram proles are sup-
ported as standard:
- FC protocol, which is a prole adapted to Dan-
foss.
- Prodrive protocol, which supports the prodrive
prole
See Serial communication for FCD 300 for further
details of telegram proles.
Fieldbus option
The increasing information requirements in industry
make it necessary to collect or visualize many differ-
ent process data. Important process data help the
system technician with the daily monitoring of the
system. The large amounts of data involved in major
systems make a higher transmission speed than
9600 baud desirable.
Probus is a eldbus system, which can be used for
linking automation devices such as sensors and
actuators with the controls by means of a two-
conductor cable.
Probus DP is a very fast communication protocol,
made specially for communication between the au-
tomation system and various types of equipment.
Danfoss FCD 300 can be supplied with the Probus
®
DP in a 3 mbit and a 12 mbit version. Units with
Probus protocol can either be controlled by FC pro-
tocol or Prodrive protocol.
Probus is a registered trade mark.
MG.04.A1.02 - VLT is a registered Danfoss trade mark
9
Introduction to FCD 300

Table of Contents

Other manuals for Danfoss VLT FCD 305

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCD 305 and is the answer not in the manual?

Danfoss VLT FCD 305 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCD 305
CategoryDC Drives
LanguageEnglish

Related product manuals