Troubleshooting
28
POWERSCAN™ PM/PBT9600
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Nothing happens
when the scan button
is pulled.
No power to the
reader.
Check system power.
Ensure power supply
is connected.
Interface or
power cables are
loose.
Ensure all cable
connections are
secure.
LED comes on, but
bar code is not
decoded.
Reader not
programmed for
correct bar code
type.
Ensure reader is
programmed to read
the type of bar code
scanned. Refer to the
PRG for more
information.
Bar code label is
unreadable.
Check the label to
ensure it is not
defaced. Try to scan
another bar code type.
Distance between
reader and bar
code is incorrect.
Move imager closer to
or further from the bar
code.
Bar code is decoded
but not transmitted
to the host.
Reader not
programmed for
the correct host
type.
Scan the appropriate
host type bar code.
Refer to the PRG for
more information.
NOTE: For detailed troubleshooting, refer to the
PRG (Product Reference Guide).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM9600 Series and is the answer not in the manual?

Datalogic PowerScan PM9600 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PM9600 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals