Keyboard Wedge
Product Reference Guide
287
Keyboard Wedge
Wedge Quiet Interval
This option specifies the amount of time to look for keyboard activity before
the reader breaks the keyboard connection in order to transmit data to host.
The selectable range for this feature is from 0 to 990ms in 10ms increments.
NOTE
This feature applies ONLY to the Keyboard Wedge interface.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
2.
Divide the desired setting by 10 (setting is in 10ms increments). Pad the
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad
, that
represent the duration which was determined in the steps above. You will
hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure to set the Wedge Quiet Interval. See
Table 12
for
some examples of how to set this feature.
Table 12. Timeout Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
10ms 150ms 600ms 850ms
2
Divide by 10 (and pad with
le
ading zeroes)
01 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT WEDGE QUIET INTERVAL SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
NOTE
If you m
ake a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.