112 A-Class
Fault Messages (continued)
Displayed Message Description Possible Solution(s)
TOP OF FORM FAULT
The printer could not find a
TOF mark within the
maximum length setting,
or TOF was encountered in
an unexpected place.
;
When the SENSOR
TYPE is REFLECTIVE,
this indication is given
for Out Of Stock.
Check the following possibilities:
Calibration may be necessary
(see Section 3.4);
The Media Sensor may need
adjustment (see Section 3.2);
The Media Guide may need
adjustment (see Section 3.1);
The Leveling Cam may need
adjustment (see Section
5.3.1);
The maximum label length
may need to be increased
(see Section 4.2.1); or
The Media Sensor may need
to be cleaned (see Section
5.5.4).
6.2 Hex Dump Mode
Hex Dump Mode is a useful diagnostic tool for debugging label formats and hardware
problems, as received host data strings are printed without interpretation by the printer.
To enter Hex Dump Mode, press the MENU Key and select DIAGNOSTICS. Go to HEX
DUMP MODE then select ENABLED and press the ENTER Key. Exit the menu, saving your
changes.
Afterward, HEX DUMP MODE will be displayed and all received data will be printed in
hexadecimal code (along with the ASCII equivalents); see example below:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-Class A-4212 and is the answer not in the manual?

Datamax A-Class A-4212 Specifications

General IconGeneral
BrandDatamax
ModelA-Class A-4212
CategoryLabel Maker
LanguageEnglish

Related product manuals