A-Class 77
Step
Action Displayed Message Comment
B
Press the MENU Key.
Then, with MEDIA
SETTINGS highlighted,
press the ENTER Key.
MEDIA SETTINGS
Press the ESC Key to
abort this procedure.
C
Using the DOWN ARROW
Key, scroll to SENSOR
CALIBRATION then press
the ENTER Key. Scroll to
ADVANCED ENTRY and
press the ENTER Key.
ADVANCED ENTRY
Press the ESC Key to
abort this procedure.
D
Scroll to SENSOR GAIN
then press the ENTER Key.
SENSOR GAIN
Press the ESC Key to
abort this procedure.
E
Place the label under the
Sensor Eye Mark and latch
the Head Lift Lever. Using
the DOWN ARROW Key,
scroll to GAIN TRAN 00
and press the ENTER Key.
GAIN TRAN
*00 (0 – 31)
<yyy>
- Or, for reflective media:
GAIN REFL
*00 (0 – 31)
<yyy>
If using preprinted
labels, ensure that
the sampling area is
free of text, graphics,
and perforations.
After ENTER is
pressed, an asterisk
(*) appears to denote
selection.
F
Record the sensor reading
(‘yyy’) as a Label Value in
a table similar to the one
shown below, with 32
rows, four columns, and
similar headings.)
GAIN TRAN
*00 (0 – 31)
<yyy>
- Or, for reflective media:
GAIN REFL
*00 (0 – 31)
<yyy>
The sensor reading,
where ‘yyy’ represents
the numeric sample, is
useful in locating the
best sensor position over
the media.
Sample Calibration Table
Gain Number Label Value TOF Value Difference Value
00 252
01
02
31
(continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-Class A-4212 and is the answer not in the manual?

Datamax A-Class A-4212 Specifications

General IconGeneral
BrandDatamax
ModelA-Class A-4212
CategoryLabel Maker
LanguageEnglish

Related product manuals