Page: 53
With the “TEST” button system test can be performed. Additionally, the Desiccator Status
can be checked. (See section 21.2 Functional Buttons for more details.)
Also, cleaning interval at OMD-24 EVA can be managed from minimum 1 minute and
maximum 8 hours. By “0” auto clean will be off.
3. Data Logger Operation Buttons
The “Log” buttons are used to operate the integrated data logger. These buttons show a
live display, in which the current data from alarm status, the external separator
additionally, the oil content, the device status, and a reserve is recording to IMO
Requirements. That data can be shown as a graphical or a text based recording at any
particular time. All the information will be recorded every 15 seconds. All recorded data
is available for more than 18 months.
With the arrow buttons, the data can be navigated.
The internal clock is factory set for GMT, Greenwich Mean Time and cannot be changed
or adjusted. The internal clock is adjusted to be within +/- 2 minutes of GMT in production.
A few minutes of derivation per year of operation should be expected. (See section 21.3
Data Logger Operation Buttons for more details.)
See Section 21. Appendix for more details about the buttons.