6 Enter the directory cd /opt/Marvell and run the command at the CLI normally.
NOTE: ESXi 6.5 U1 or ESXi 6.0 U3 P06 is the minimum requirement to install the BOSS-S1 CLI utility.
Supported BOSS-S1 CLI commands
The following table lists the supported BOSS-S1 command line interface (CLI) commands. For more information about the commands, type
> help.
NOTE: The BOSS-S1 CLI utility only supports the following commands:
Table 5. Supported CLI commands
CLI commands Description Windows Usage Linux / VMware Usage
info -o hba
Display BOSS-S1 controller
information.
mvsetup info -o hba ./mvcli info -o hba
info -o vd
Display virtual drive information. mvsetup info -o vd ./mvcli info -o vd
info -o pd
Display physical drive information. mvsetup info -o pd ./mvcli info -o pd
smart -p <PD_ID>
Display SMART information of
physical drive.
mvsetup smart -p 0 ./mvcli smart -p 0
NOTE: SMART reports the health status of the M.2 disks. Refer to the SMART status return once the command is executed.
event
Display controller events. mvsetup event ./mvcli event
NOTE: There may be inconsistency in the events that are listed in BOSS CLI and other management interfaces that include
Dell EMC Open Manage Storage Services.
flash
Enables you to perform controller
rmware upgrade.
mvsetup ash -a update -f
<image binary le> -t raw
./mvcli ash -a update -f
<image binary le> -t raw
help
Details help for all commands or for
only one command.
mvsetup help info ./mvcli help info
26 BOSS-S1 CLI commands