BOSS-S1 CLI displays No Adapter Found error in Linux
Issue: BOSS-S1 CLI displays No Adapter Found error message in the Linux operating system.
Probable Cause: Using the BOSS-S1 CLI, when you run the CLI commands using non-administrative user privileges, the error No
Adapter found is displayed.
Corrective Action: Use root/sudo administrator privilege while you run the CLI commands.
LC log displays fan unavailability error
Issue: LC log displays The BOSS-S1 device does not have a fan installed in it error message.
Probable Cause: Currently there is no fan requirement for BOSS-S1, which might be required in future based on M.2 thermal
requirement.
Corrective Action: No action required. This error message can be ignored.
Updating BOSS-S1 controller rmware using iDRAC or
LC fails
Issue: Updating rmware on a BOSS-S1 controller from versions A00 to A01 using iDRAC/LC fails.
Probable Cause: The systems management support is not enabled in the rmware version A00. iDRAC/LC update is supported only
on the rmware version A01 and later.
Corrective Action: Use UEFI, OS DUP, or BOSS -S1 CLI to update rmware.
Physical disk size not updated in iDRAC
Probable Cause:
When Collect System Inventory on Reboot (CSIOR) is disabled, iDRAC displays partial information about BOSS-S1
components.
Corrective Action: Ensure that CSIOR is enabled in iDRAC for the server to collect the system inventory on reboot.
NOTE: Ensure that the BOSS-S1 controller rmware and iDRAC rmware are updated to the latest
version.
Physical disk/Virtual disk missing in iDRAC
Probable Cause:
When Collect System Inventory on Reboot (CSIOR) is disabled, iDRAC displays partial information about BOSS-S1
components.
Corrective Action: Ensure that CSIOR is enabled in iDRAC for the server to collect the system inventory on reboot.
NOTE: Ensure that the BOSS-S1 controller rmware and iDRAC rmware are updated to the latest
version.
28 Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC Boot Optimized Server Storage-S1 and is the answer not in the manual?

Dell EMC Boot Optimized Server Storage-S1 Specifications

General IconGeneral
BrandDell EMC
ModelBoot Optimized Server Storage-S1
CategoryServer
LanguageEnglish

Related product manuals