33
9 Electrical installation
Connecting the mains cable
– Remove the screws securing the cover “A” (fig. 9.1) on the rear of the cooker.
– Remove the screws from the cable clamp “D” (fig. 9.1) and feed the cable through the
clamp.
– Connect the live and neutral wires.
– Take up any slack in the cable and secure with cable clamp “D”.
– Replace cover “A”.
Fig. 9.1
D
B
PE
A
N
L
This cooker must be supplied via a suitable double pole isolating switch.
The electrical connection must be connected to the terminal block “B” (fig. 9.1) and must
only be carried out by a qualified electrician. A cable of the correct rating of this appliance
must be use 3x1,5 mm
2
.
For your safety please read the following information:
This appliance must be installed by a qualified technician according with the current local
regulations and in compliance with the manufacturer instructions.
All electrical wiring must be in compliance with the appropriate IEE regulations and carried
out by a qualified electrician .
Before installing the cooker the electricity must be turned off.
Warning! This appliance must be earthed