Chapter 10 Function Cards
10-23
10
10.2.8 AS-FPFN02
When AS-FPFN02 is installed on AS300 PLC CPU, this communication card can work independently and does NOT
occupy the communication port of PLC CPU. AS-FPFN02 can act as a PROFINET adapter and connect to a PROFINET
scanner to exchange data on the PROFINET Network (PN). When AS-FPFN02 is installed on AS00SCM-A, Delta AS
Series I/O modules can be used remotely. However Delta software does NOT support PN network configuration, you can
use software from the PN scanner for editing the PN parameters. After editing, you need to download the updated
parameters to the scanner and then the scanner transfers the settings to AS-FPFN02.
10.2.8.1 Supported Firmware Versions
When installed on AS300 series PLC CPU:
The firmware of AS300 Series PLC should be V1.08 or later.
The firmware of AS-FPFN02 should be V1.00 or later.
When installed on AS00SCM:
The firmware of AS00SCM should be V2.06 or later.
The firmware of AS-FPFN02 should be V2.00 or later.
10.2.8.2 Features
When AS-FPFN02 is installed on AS300/AS00SCM Series PLC, it acts as a PROFINET device and
exchanges data with PN Controller.
Architecture: you can use software from the PN scanner for editing the PN parameters. After editing, you
need to download the updated parameters to the scanner and then the scanner transfers the settings to AS-
FPFN02.