Chapter 7 Motion Control ASDA-A2R Series
Revision December, 2014 7-9
7.2.2 Description of Data Array
Many functions of motion control, such as CAPTURE, COMPARE and E-Cam are the
data that needs to be saved in large amount of memory space, therefore, the servo
drive reserves a continuous internal space to satisfy the need. The main feature of the
data array is as the followings:
Feature Introduction of Data Array
Usage Save the captured data of CAPTURE
Save the compared value of COMPARE
Save the contour table of E-Cam
Note: The system does not partition off the data array into the
individual space of CAP, CMP and E-Cam. The user could
program it according to the demand. Therefore, the space
might be overlapped. Please pay close attention to it when
using.
Size of Data Array 32-bit integer x 800 (refer to P5-10)
Each data has its corresponding address. Specify the
address is a must when reading or writing the data.
The 800 data is from 0 to 799.
Data Retained Manually set up the saving (P2-08 = 30, 35) is a must and
the data should be saved in EEPROM of the servo drive.
Save the data when it is Servo Off.
The data will be loaded into data array automatically when it
is Servo On.
Accessing Window Should be access via parameter P5-10 ~ P5-13.
The content of data array cannot be read or wrote directly, reading or writing the data
must via parameter P5-10 ~ P5-13. The description of the parameters is as the
followings:
Description of Related Parameter about Data Array
Parameter Name Description
P5-10
Size of data
array
Return the size of data array (read-only)
P5-11
Reading /
writing
address
Set the desired address of reading and writing
P5-12 Reading /
writing
window #1
Read via panel: After reading the content of P5-11, the
value of P5-11 will not change.
Write via panel: After writing the content of P5-11, the value
of P5-11 will increase 1 automatically.
------------------------------------------------------------------------------
Read via communication: After reading the content of
P5-11, the value of P5-11 will
increase 1 automatically.
Write via communication: After writing the content of P5-11,
the value of P5-11 will increase 1
automatically.
P5-13 Reading /
writing
window #2
Read via panel: After reading the content of P5-11, the
value of P5-11 will increase 1
automatically.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2R-0221 Series and is the answer not in the manual?

Delta ASD-A2R-0221 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2R-0221 Series
CategoryServo Drives
LanguageEnglish

Related product manuals