Delta Electronics Servo Press E-Series Installation and Maintenance Instructions
12
4. Equipment Care and Maintenance
4.1 Applying Oil to Equipment
High temperature lubricating grease has been applied to the servo electric cylinder at the factory. Please
refer to the table below for the time intervals for regular lubrication of the bearings and ball screws.
Average rotation speed of ball screw (RPM)
Recommended time intervals for applying oil
(Hr)
250 10,000
500 10,000
1,000 8,000
1,500 7,000
2,000 5,800
2,500 5,000
3,000 4,000
It is recommended to use Mobil SHC220 grease. The working temperature range of this grease is
-40°C to 177°C
*Recommended oil injector: KCG-470H (Brand: Alba)
*Single injection volume: 40 ml
Oil hole