ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-3
6.2 Position Mode
The followings describe the related information and settings of position mode.
6.2.1 Position Command in PT Mode
PT, position command is the pulse input from terminal block. There are three types of pulse and
each type has positive/negative logic which can be set in parameter P1-00. See as the followings.
P1-00
PTT External Pulse Input Type
Address: 0100H
0101H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 6.2.1
Operational
Interface
Panel / Software Communication
Default
0x2
Control
Mode
PT
Unit
-
Range
0 ~ 1132
Data Size
16-bit
Format
Hexadecimal
Settings
Pulse Type
0: AB phase pulse (4x)
1: Clockwise (CW) and Counterclockwise (CCW) pulse
2: Pulse + symbol
Other settings: reserved