ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-161
P5-xx Motion Setting Parameters
P5-00 ~
P5-02
Reserved
P5-03 PDEC Deceleration Time of Auto Protection
Address: 0506H
0507H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0XEEEFEEFF
Control
Mode
ALL
Unit
-
Range
0x00000000 ~ 0xFFFFFFFF
Data Size
32-bit
Format
Hexadecimal
Settings
The parameter setting is divided into D, C, B, A, W, Z, Y, X
(hexadecimal), including:
1. The deceleration time when activating the auto-protection function:
OVF (DO.0x11, poisiiton command / feedback overflows), CTO
(communication timeout AL020), SPL, SNL, PL, NL
2. Deceleration time of Stop Command: STP
Item D C B A W Z Y X
Function STP
PFQS
CTO OVF SNL SPL NL PL
Range
~ F
0F
~ F ~ F ~ F ~ F ~ F ~ F
0 ~ F is used to indexing the deceleration time of P5-20~P5-35.
For example: If X is set to A, then the deceleration time of PL is
determined by P5-30.
P5-04 HMOV Homing Mode
Address: 0508H
0509H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
PR
Unit
-
Range
0 ~ 0x128

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals