Chapter 8 Parameters ASDA-A2
8-160 Revision February, 2017
400V Series
P4-24 LVL Level of Under voltage Error
Address: 0430H
0431H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
320
Control
Mode:
ALL
Unit:
V (rms)
Range:
140~380
Data Size:
16-bit
Format:
Decimal
Settings:
When the voltage of DC BUS is lower than P4-24*
2
, the under
voltage alarm occurs.