Chapter 6 Control Mode of Operation ASDA-A2
6-10 Revision February, 2017
Relevant Parameters:
P1-34 TACC Acceleration Constant of S-Curve
Address: 0144H
0145H
Operational
Interface:
Panel / Software Communication
Related Section:
6.3.3
Default:
200
Control
Mode:
S
Unit:
ms
Range:
1 ~ 65500
Data Size:
16-bit
Format:
Decimal
Settings:
Acceleration Constant of Rotary Motor:
The time that speed command accelerates from 0 to the rated speed.
Acceleration Constant of Linear Motor
The time that speed command accelerates from 0 to 5m/s.
P1-34, P1-35 and P1-36, the acceleration time of speed command
from zero to the rated speed, all can be set individually. Even when P1-
36 is set to 0, it still has acceleration / deceleration of trapezoid-curve.
NOTE
1)When the source of speed command is analog, and P1-36 is set to
0, it will disable S-curve function.
2)When the source of speed command is analog, the max. range of
P1-34 will be set within 20000 automatically.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals