Chapter 11 Summary of Parameter SettingsMS300
251
10 Speed Feedback Control Parameters
Pr.
Explanation
Settings
Default
10-00
MI7 One-Phase Pulse
Input Type Selection
0: Disabled
5: Pulse input (MI7)
0
10-01
MI7 One-Phase Pulse
Input Pulses per
Revolution
1–20000
600
10-02
MI7 One-Phase Pulse
Input Type Setting
0: Disable
5: Single-phase input (MI7)
0
10-04
Electrical Gear at Load
Side A1
1–65535
100
10-05
Electrical Gear at Motor
Side B1
1–65535
100
10-06
Electrical Gear at Load
Side A2
1–65535
100
10-07
Electrical Gear at Motor
Side B2
1–65535
100
10-10
MI7 One-Phase Pulse
Input Stall Level
0: No function
0–120%
115
10-11
Detection Time of MI7
One-Phase Pulse Input
Stall
0.0–2.0 sec.
0.1
10-12
MI7 One-Phase Pulse
Input Stall Action
0: Warn and continue operation
1: Fault and ramp to stop
2: Fault and coast to stop
2
10-13
MI7 One-Phase Pulse
Input Slip Range
0: Disable
0–50%
50
10-14
Detection Time of MI7
One-Phase Pulse Input
Slip
0.0–10.0 sec.
0.5
10-15
MI7 One-Phase Pulse
Input Stall and Slip Error
Action
0: Warn and continue operation
1: Fault and ramp to stop
2: Fault and coast to stop
2
10-16
Pulse Input Type Setting
0: Disabled
5: Single-phase input (MI7)
0
10-17
Electrical Gear A
1–65535
100
10-18
Electrical Gear B
1–65535
100
10-21
Pulse Input Speed
Command Low Pass
Filter Time
0.000–65.535 sec.
0.100