Explanation of exception codes:
Exception code
Explanation
01
Illegal function code:
The function code received in the command message is not available for the AC
motor drive.
02
Illegal data address:
The data address received in the command message is not available for the AC
motor drive.
03
Illegal data value:
The data value received in the command message is not available for the AC
motor drive.
04
Slave device failure:
The AC motor drive is unable to perform the requested action.
10
Communication time-out:
If Pr.09.03 is not equal to 0.0, and Pr.09.02 = 02, and there is no communication
on the bus during the time-out detection period (Pr.09.03), the keypad displays
“cE10”.
7. Communication program for a PC:
The following is a simple example of how to write a communication program for Modbus ASCII mode on a
PC in the C language.
#include<stdio.h>
#include<dos.h>
#include<conio.h>
#include<process.h>
#define PORT 0x03F8 /* the address of COM1 */
/* the address offset value relative to COM1 */
#define THR 0x0000
#define RDR 0x0000
#define BRDL 0x0000
#define IER 0x0001
#define BRDH 0x0001
#define LCR 0x0003
#define MCR 0x0004
#define LSR 0x0005
#define MSR 0x0006
unsigned char rdat[60];
/* read 2 data from address 2102H of AC drive with address 1 */
unsigned char tdat[60]={':','0','1','0','3','2','1','0',’2', '0','0','0','2','D','7','\r','\n'};
void main(){
int i;
outportb(PORT+MCR,0x08); /* interrupt enable */
outportb(PORT+IER,0x01); /* interrupt as data in */
outportb(PORT+LCR,(inportb(PORT+LCR) | 0x80));
/* the BRDL/BRDH can be access as LCR.b7==1 */
outportb(PORT+BRDL,12); /* set baudrate=9600, 12=115200/9600*/
outportb(PORT+BRDH,0x00);
outportb(PORT+LCR,0x06); /* set protocol, <7,N,2>=06H, <7,E,1>=1AH, <7,O,1>=0AH,
<8,N,2>=07H, <8,E,1>=1BH, <8,O,1>=0BH */
for(i=0;i<=16;i++){
while(!(inportb(PORT+LSR) & 0x20)); /* wait until THR empty */
outportb(PORT+THR,tdat[i]); /* send data to THR */ }
i=0;
while(!kbhit()){
if(inportb(PORT+LSR) & 0x01){ /* b0==1, read data ready */
rdat[i++]=inportb(PORT+RDR); /* read data form RDR */
} } }
09.05 Reserved

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Delta VFD007EL43W and is the answer not in the manual?

Delta VFD007EL43W Specifications

General IconGeneral
Rated Output Current7A
Phase3-phase
Control MethodV/F Control, Sensorless Vector Control
SeriesDelta VFD-E Series
Output Voltage0 - Input Voltage
Frequency Range0 - 400 Hz
Protection FeaturesOvervoltage, Undervoltage, Overcurrent
Cooling MethodFan cooling

Summary

Preface

Safety Guidelines Before Operation

Read safety guidelines before connecting power to the AC motor drive.

Chapter 1 Introduction

Preparation for Installation and Wiring

Install the AC motor drive in an environment with specific conditions.

Chapter 2 Installation and Wiring

Wiring Overview and Precautions

Details wiring precautions and diagrams for main and control circuits.

Main Circuit Connections

Describes how to connect the main power terminals and output terminals.

Control Terminals Functionality

Explains the function of each control terminal for input and output signals.

Chapter 3 Keypad and Start-up

Digital Keypad Operation and Display

Describes the functions of the digital keypad buttons and displays.

Trial Run Procedure

Guides through the initial test run to verify motor operation and direction.

Chapter 4 Parameters

Chapter 5 Troubleshooting

Over-Current Faults (oc)

Explains causes and corrective actions for over-current conditions.

Motor Not Running or Performing Incorrectly

Guides through diagnosing why the motor doesn't run or perform as expected.

Chapter 6 Fault Code Information and Maintenance

Fault Code Explanations and Corrective Actions

Lists fault codes, descriptions, and corrective actions for drive errors.

Maintenance and Inspection Schedule

Provides a schedule and methods for regular inspection and maintenance.

Appendix C How to Select the Right AC Motor Drive

Related product manuals