EasyManuals Logo
Home>Delta>DC Drives>VFD040EL43W

Delta VFD040EL43W User Manual

Delta VFD040EL43W
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
Chapter 4 Parameters
VFD-EL-W
4-25
Keep Running when Frequency Command is Lost
Applications Purpose Functions
Related
Parameters
Air conditioners For continuous operation
When the frequency command is lost
because of a system malfunction, the AC
motor drive still runs. Suitable for
intelligent air conditioners.
02.06
Output Signal during Running
Applications Purpose Functions
Related
Parameters
General application;
mechanical brake
Provide a signal for
running status
Signal available to stop braking (brake
release) when the AC motor drive is
running. (This signal disappears when
the AC motor drive is free-running.)
03.00
Output Signal in Zero Speed
Applications Purpose Functions
Related
Parameters
General application;
machine tools
Provide a signal for
running status
When the drive’s output frequency is
lower than the minimum output
frequency, gives a signal for an external
system or control wiring.
03.00
Output Signal at Set Frequency
Applications Purpose Functions
Related
Parameters
General application;
machine tools
Provide a signal for
running status
When the drive’s output frequency
reaches the set frequency (from the
frequency command), gives a signal for
an external system or control wiring
(frequency reached).
03.00
Output Signal at Over-torque
Applications Purpose Functions
Related
Parameters
Machine tools, fans,
pumps, and extruders
To protect machines and
for reliable operation
When the motor over-torque is larger
than the drive's setting level, gives a
signal to prevent the machine from
damage due to load.
03.00,
06.04–06-05
Output Signal at Low Voltage
Applications Purpose Functions
Related
Parameters
General application
Provide a signal for
running status
When low voltage is detected after the
motor detects the P-N voltages, gives a
signal for an external system or control
wiring.
03.00
Output Signal at Desired Frequency
Applications Purpose Functions
Related
Parameters
General application
Provide a signal for
running status
When the drive’s output frequency
reaches the desired frequency, gives a
signal for an external system or control
wiring.
03.00–03.02

Table of Contents