Chapter 1 IntroductionME300
1-5
1-5 RFI Jumper
The drive contains Varistors / MOVs that are connected from phase to phase and from phase to ground to
protect the drive against mains surges or voltage spikes.
Because the Varistors / MOVs from phase to ground are connected to ground with the RFI jumper,
removing the RFI jumper disables the protection.
(1) In models with a built-in EMC filter, the RFI jumper connects the filter capacitors to ground to form a
return path for high frequency noise. This isolates the noise from contaminating the mains power.
Removing the RFI jumper strongly reduces the effect of the built-in EMC filter.
(2) Although a single drive complies with the international standards for leakage current, an installation
with several drives with built-in EMC filters can trigger the RCD. Removing the RFI jumper can help,
but the EMC performance of each drive is no longer guaranteed.
Frame A–D Screw Torque:
4–6 kg-cm / [3.5–5.2 lb-in.] / [0.39–0.59 Nm]
Loosen the screw and remove the RFI jumper (as shown below). Fasten the screw again after you remove
the RFI jumper.
Frame B–D (model with built-in EMC filter)
Remove the RFI jumper with a screwdriver (as shown below).