EasyManuals Logo
Home>Delta>DC Drives>VFD1A6ME21ANNAA

Delta VFD1A6ME21ANNAA User Manual

Delta VFD1A6ME21ANNAA
403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #393 background imageLoading...
Page #393 background image
Chapter 15 Safe Torque Off FunctionME300
15-2
15-1 Basic Function Description
The ME300 series provide a Safe Torque Off (STO) function. The ME300 series use dual-channel S1
and S2 signal inputs to turn off IGBT switching, further preventing the generation of motor torque in order
to achieve a safe stop. Refer to Figure 1 for the Safe Torque Off function circuit diagram.
The ME300 Safe Torque Off function meets the following international standards:
ISO 13849-1: 2015 Category 3 PL d
IEC 61508 SIL2
EN 62061 SIL CL 2
EN 60204-1 Category 0
Figure 1: The circuit diagram for the Safe Torque Off function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD1A6ME21ANNAA and is the answer not in the manual?

Delta VFD1A6ME21ANNAA Specifications

General IconGeneral
BrandDelta
ModelVFD1A6ME21ANNAA
CategoryDC Drives
LanguageEnglish

Related product manuals