PROCEDURE AFTER REPLACING THE MICROPROCESSOR, ETC
The procedure after replacing the u-COM (Microprocessor), ash ROM, etc. is as follows.
PCB Name
Ref. No. Description
Procedure
after
Replacement
Remark
Digital IC711 STM32F101ZG B SOFTWARE: Main
Digital
IC722 MX25L3206EM2I-12G B SOFTWARE: GUI ROM
Digital
IC742 MX25L8006EM2I-12G B SOFTWARE: DSP ROM
Procedure after Replacement
A : The software has been written. The software is not written at the time of replacement.
B : The software has been written. The software may need to be rewritten by version updates. Check the version.
C : The software has not been written. The software needs to be written after replacement.
See "Firmware Update Procedure" for information on writing the software.
D : The software has been written. Be sure to rewrite with the latest software for your service region.
See "Firmware Update Procedure" for information on writing the software.
27