21
1. InitializationMode
1.1. Operations
Hold down buttons below at the same time and press the power button to turn on the power.
"SOUND MODE
1
", "PRESET +" (AVR-S510BT)
"PRESET +", "TUNE +" (AVR-X520BT / X518CI)
Release the buttons after conrming that the display ashes in intervals of approximately 1 second.
1.2. Actions
Initialize this unit.
Note:Settings for the tuner step are not initialized.
2. VersionDisplayMode
2.1. Operations
Hold down buttons below at the same time and press the power button to turn on the power.
"PRESET +", "TUNE -" (AVR-S510BT)
"TUNE +", "DIMMER" (AVR-X520BT / X518CI)
Press the button "STATUS" to display the versions.
2.2. Actions
Press the "STATUS" button to display the versions in the following order.
Error information(See 2.4. Error display) →
q
Model destination information →
w
Main-µcom version →
e
Main IAP →
r
DSP version →
t
OSD version
→
y
USB version
→ Normal display
When an error has occurred in this unit, the error information is displayed initially when entering this mode. (5 seconds)
Condition Display
q
Model destination information
AVR-S510BT
E3 model
A V R - S 5 1 0 E 3
AVR-X520BT
E2 model
A V R - X 5 2 0 E 2
AVR-X520BT
E1C model
A V R - X 5 2 0 E 1 C
AVR-X518CI
E1C model
A V R - X 5 1 8 C I
w
Main-µcom version
M a i n . * * * * - V * . * *
e
Main IAP
M a i n I A P V * * . * *
r
DSP version
D S P . * . * . *
t
OSD version
O S D : * * . * *
y
USB version
U S B . * * . * * . * *
2.3. Cancelingthemode:
Press the
X
button to turn the power off.
2.4. Errordisplay
See the following table for each "Error information" display and its contents (status).
Condition - Display
DSP NG When DSP boot, executing DSP reset makes to becomes error.
D S P E R R O R 0 1
DSP OK (No error display, version display only)
f
f
f