Hardware Rack Mounting (ConnectPort TS 16 models)
Digi Connect Family and ConnectPort TS Family
27
n For AC Supply Systems:
l Locate the AC supply source within the same premises as the equipment you are using.
The following image shows a ConnectPort TS 16 VAC with an AC plug.
The following image shows a ConnectPort TS 8 VAC with a barrel jack.
n For DC Supply Systems:
l Connect equipment to a DC supply source (reliably earthed) that is electrically isolated
from the AC source.
l Provide a readily accessible disconnect device and protective device a fixed wiring for a DC
power supply suitable for the specified rated voltage and current. Disconnect and
protective devices to be rated 2A Amps maximum.
l Directly connect the equipment chassis to the DC supply system grounding electrode
conductor or a bonding jumper from a grounding terminal bar (or bus) that is connected to
the DC supply system grounding electrode conductor. In DC supply systems, the protective
grounding wire must be a minimum 18AWG.
The following image shows the ConnectPort TS 16 48VDC with a terminal block.