5
Model No. Nominal
Capacity
(BTU HR)
Cooling
Electrical
Rating
Compressor
Rated Load
Amps
Compressor
Locked
Rotor
Amps
Fan Motor
Rated Load
Amps
Fan Motor
Locked
Rotor
Amps
Refrigerant
R-410A
(oz)
Minimum
Wire Size*
AC Circuit
Protection
***Installer
Supplied
Minimum
Generator
Size**
1 Unit / 2 Units
641815H85X 13,500 120 Vac
60 Hz 1 ph
12.6 63.0 2.6 8.5 19.0 12 AWG
Copper
Up to 24'
20 Amp 3.5 kW / 5.0 kW
641816.80X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641816C35X Hi Cap 12.3 61.0 3.3 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641816C75X Hi Cap 12.9 52.0 2.6 8.5 21.5 20 Amp 3.5 kW / 5.0 kW
641816C85X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641816H75X HI Cap 12.9 52.0 2.6 8.5 21.5 20 Amp 3.5 kW / 5.0 kW
641816H85X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641835.80X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
641835C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW
641835C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW
641835C85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
641835H75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW
641835H85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
641915.80X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
641915C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW
641915C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW
641915C85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
641916.80X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641916C35X Hi Cap 12.3 61.0 3.3 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641916C75X Hi Cap 12.9 52.0 2.6 8.5 21.5 20 Amp 3.5 kW / 5.0 kW
641916C85X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
641935.80X 13,500 12.5 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
641935C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW
641935C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW
641935C85X 13,500 12.5 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
651815.80X 13,500 13.1 63.0 2.6 8.5 24.0 20 Amp 3.5 kW / 5.0 kW
651815C35X 13,500 12.5 61.0 3.5 10.0 25.0 20 Amp 3.5 kW / 5.0 kW
651815C75X 13,500 12.7 52.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
651815C85X 13,500 13.1 63.0 2.6 8.5 24.0 20 Amp 3.5 kW / 5.0 kW
651815H75X 13,500 12.7 52.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW
651815H85X 13,500 13.1 63.0 2.6 8.5 24.0 20 Amp 3.5 kW / 5.0 kW
651816.80X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW
651816C35X HI Cap 12.3 61.0 3.3 8.5 24.0 20 Amp 3.5 kW / 5.0 kW
651816C75X Hi Cap 13.0 52.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
651816C85X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW
651816H75X Hi Cap 13.0 52.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
651816H85X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW
651916.80X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW
651916C35X HI Cap 12.3 61.0 3.3 8.5 24.0 20 Amp 3.5 kW / 5.0 kW
651916C75X Hi Cap 13.0 52.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW
651916C85X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW
* For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B. Roof Requirements
● A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this
unit. This opening is part of the return air system of the unit and MUST be nished in accordance with NFPA 1192.
● Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
● Minimum of 2 inches and maximum of 4 inches distance between roof to ceiling of RV.
SPECIFICATIONS