CT4110, CTS4110 Warranty
31
I
10 Warranty
The statutory warranty period applies. If the product is defective, please contact your
retailer or the manufacturer's branch in your country (see the back of the instruction
manual for the addresses).
For repair and guarantee processing, please include the following documents when
you send in the device:
• A copy of the receipt with purchasing date
• A reason for the claim or description of the fault
NOTE
You can find the type plate in the cassette housing after removal of the
cassette.
Fault Possible cause Remedy
Toilet no longer flushes. Faulty fuse.
Cassette not inserted.
Cassette full.
No power supply.
Electronics defective.
Pump defective.
Solenoid valve defective.
Screen of solenoid valve is
dirty.
Replace the fuse (see chapter
“Replacing the fuse in the
operating unit” on page 30).
If there are repeated failures,
check the electrical connec-
tions!
Replace defective parts.
Cassette tank leaks. Seal worn. Replace the cassette seal
(see chapter “Replacing the
cassette seal” on page 29).
No level indication. The float in the cassette tank is
hung up or jammed by toilet
paper.
Clean the float in the cassette.
Do not use a
high-pressure cleaner!
CT4000--O--USA.book Seite 31 Dienstag, 6. März 2018 1:39 13