28 Quick reference guide | Atlan SW 2.0n
Ending operation
6 Ending operation
The quick reference guide does not replace the instructions for use. Any use of the
medical device requires full understanding and strict observation of the instructions for use.
6.1 At the end of the OR day
Dräger recommends shutting down the device during longer periods of non-use such as
overnight or on weekends. This can lower power consumption and prolong the life span of
the medical device without negatively influencing device availability.
Before shutting down, the device can optionally be prepared for automatic switch-on
including an automatic system test.
6.1.1 End of operation
1. Make sure that all flow control valves are closed.
2. Press the key.
3. Follow the instructions on the screen.
6.1.2 Programming the system test (Auto On option)
Using the Auto On function, the device can be programmed so that it performs an automatic
system test and is tested at a specific time.
During the initialization, the Auto On function checks the components that frequently cause
irregularities, e.g., high leakage, insufficient gas supply. After that, the device remains in
Standby mode until the automatic system test, or it is shut down.
1. Press the key.
2. Touch the Auto On preparation button.
3. Prepare the device in accordance with the instructions on the screen.
4. Set the desired day and time for the device to be ready for operation.
5. Select whether the device should remain in Standby mode or be shut down.
6. Touch the Start button.
7. If necessary, observe any messages that occur.
After the Auto On initialization is complete, the time remaining until the system test is
displayed in Standby mode. While the device is being shut down, the corresponding symbol
is shown in the status display, see page 12.
For a final test of the operational readiness of the device, it is only necessary to perform
some brief manual checks after the automatic system test.
6.2 Storing the device
Proceed as follows when the device is to be disconnected from the mains power supply for
longer than 2 weeks:
1. Set the main switch to the position.
2. Disconnect the power plug. This will prevent deep discharge of the battery.
6.3 Disconnecting the mains power supply
When the device is disconnected from the mains power supply, the internal battery takes
over the function of supplying power. The status display remains active. Follow the
instructions for storing the device.
Disconnect the power plug.