5
(HH:MM), followed by the date (MM:DD:YY). Press to exit programming. If you are viewing a
‘Loss of Clock" trouble from within the trouble menu ( ), press to directly enter Date
and Time programming (see Trouble Conditions).
NOTE: Your installer may have programmed your system to display the time and date while the
keypad is idle. Press the button to temporarily clear the date and time display if desired.
Bypassing Zones
Use the zone bypassing feature when you need access to a protected area while the system is
armed, or when a zone is temporarily out of service but you need to arm the system. Bypassed
zones will not be able to sound an alarm. As a result, bypassing zones reduces the level of
security. If you are bypassing a zone because it is not working, call a service technician immedi-
ately so that the problem can be resolved and your system returned to proper working order.
Ensure that no zones are unintentionally bypassed when arming your system. Zones cannot be
bypassed once the system is armed. Bypassed zones (except for 24-hr zones) are automatically
cancelled each time the system is disarmed and must be bypassed again, if required, before
the next arming.
With the system disarmed:
Activating All Bypassed Zones
To remove bypass (all zones):
1. Press , then your access code or present your prox tag if required.
2. Press .
3. To exit bypassing mode and return to the Ready state, press .
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press , then your access code or present your prox tag if required.
2. Press .
3. To exit bypassing mode and return to the Ready state, press .
Bypass Group
A Bypass Group is a selection of zones programmed into the system. If you bypass a group of
zones on a regular basis, you can program them into a Bypass Group, so that you do not have to
bypass each zone individually. Note that only one Bypass Group can be programmed at a time.
To program a Bypass Group:
1. Press , then your access code or present your prox tag if required.
2. Enter the 2-digit numbers (01-34) of the zones to be included in the Bypass Group or use the
buttons to find the zone to be included in the Bypass Group, then press to
select the zone.
3. To save the selected zone into the group, press .
4. To exit bypassing mode and return to the Ready state, press .
NOTE: If an access code is required to enter bypassing, only the master code and codes with
Supervisory enabled can set the Bypass Group.
To select a Bypass Group when arming the system:
1. Press , then your access code or present your prox tag (if necessary).
2. Press . The next time the system is armed, the zones in this group will be bypassed.
3. To exit bypassing mode and return to the Ready state, press .
1. Press to enter the function menu. The keypad will display the
screen on the right.
2. Press or .
3. If your system is programmed to require access codes the screen
on the right will be displayed. Enter your 4-digit access code.
4. Scroll to the desired zone number using the keys, then
press to select the zone or directly enter the 2-digit number
of the zone you wish to bypass (e.g., 0 5 for zone 5).
Press (*) for <>
Enter Your
Access Code
Scroll to <>
Bypass Zones