EasyManuals Logo
Home>DSC>Security System>HS2LCDP

DSC HS2LCDP User Manual

DSC HS2LCDP
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Programming Directory
This section provides a list of all available programming options in numerical order. To program, access Installer Programming mode by keying in [*][8]
[Installer Code]. Use the scroll keys < > to navigate through the menus or jump directly to a specific section by keying in a section number and pressing
[*]. Programming consists of toggling on and off options in each section or by populating data fields. Press [*] to select options and [#] to exit to the
previous menu. For descriptions of all programming options and programming worksheets, refer to the PowerSeries Neo Reference Manual.= Default
Label Programming
000 Label Programming
000 Language Selection (01)
001 Zone Labels
- 12 -
001-128 Zone Labels 1-128
051 Zone Tamper Label
052 Zone Fault Label
064 CO Alarm Message
065 Fire Alarm Message
066 Fail to Arm Event Message
067 Alarm When Armed Event
Message
100 System Label
101-108 Partition 1-8 Labels
201- 208 Partition 1-8 Command
Output Labels
001-004 Command output 1-
4 Labels
601-604 Schedule 1- 4 Labels
801 Keypad Labels
001-016 Keypad 1-16 Labels
802 Zone Expander Labels
001-015 Zone Expander 1-
15 Labels
803 Output Expander Labels
001 Output Expander 1 Label
806 HSM2HOST Label
808 HSM2955 Label
809 Power Supply Label
001-004 Power Supply 1-4
Label
810 High Current Output Supply
Label
001-004 Power Supply 1-4
Label
815 Alternate Communicator
Label
820 Siren Label
001-016 Siren 1-16 Label
821 Repeater Label
001-008 Repeater 1-8 Label
999 Default Labels
Zone Type
001 Zone Type
001-128 Zone Types (000)
000 Null Zone
001 Delay 1
002 Delay 2
003 Instant
004 Interior
005 Interior Stay/Away
006 Delay Stay/Away
007 Delayed 24-Hour Fire
008 Standard 24-Hour Fire
009 Instant Stay/Away
010 Interior Delay
011 Day Zone
012 Night Zone
016 Final Door Set
017 24-Hour Burglary
018 24-Hour Bell/Buzzer
023 24-Hour Supervisory
024 24-Hour Supervisory
Buzzer
025 Auto Verify Fire
027 Fire Supervisory
040 24-Hour Gas
041 24-Hour CO
042 24-Hour Holdup
043 24-Hour Panic
045 24-Hour Heat
046 24-Hour Medical*
047 24-Hour Emergency
048 24-Hour Sprinkler
049 24-Hour Flood
051 24-Hour Latching
Tamper
052 24-Hour Non-Alarm
056 24-Hour High
Temperature
057 24 Hour Low
Temperature
060 24-Hour Non-Latching
Tamper
066 Momentary Keyswitch
Arm
067 Maintained Keyswitch
Arm
068 Momentary Keyswitch
Disarm
069 Maintained Keywsitch
Disarm
071 Doorbell Zone
072 Push to Set
002 Zone Attributes
001-0128 (see PowerSeries Neo
reference manual for defaults)
1 Bell Audible
2 Bell Steady
3 Door Chime
4 Bypass Enabled
5 Force Arm
6 Swinger Shutdown
7 Transmission Delay
8 Burglary Verification
9 Normally Closed EOL
10 Single EOL
11 Double EOL
12 Fast Loop/Normal Loop
Response
13 Zone 2-way Audio
Activation
14 Holdup Verification
System Times
005 System Times
000 System Area
Bell Cutoff (004 min.)
Bell Delay Time (000 min.)
Burglary Verification Timer
(060 sec.)
Holdup Verification Timer
(008 sec.)
Zone Loop Response (250 ms)
Automatic Clock Adjust (060
sec.)
001 008 System Times - Partition
1-8
Entry Delay 1 (030 sec.)
Entry Delay 2 (045 sec.) (CP-
01 030 sec.)
Exit Delay (120 sec.) (CP-01
060 sec.)
Settle Delay (010 sec.) (CP-
01 000 sec.)
900 Bell Delay Partition Mask
(Y,Y,Y,Y,Y,Y,Y,Y)
901 Daylight Savings Begin:
Month (003)(AUS 010)(NZ
009)(SA004)(FRA 004)
Week (005)(AUS 005)(NZ
005)(SA 001)(CE 005)(C 005)
(FRA 001)(UK 005)
Day (000)
Hour (001)(CE 001)(C 001)
(UK001)
Increment (001)
902 Daylight Savings End
Month (010)(AUS 003)(NZ
004)(SA010)(C 010)(FRA
010)(UK010)
Week (005)(AUS 005)
(SA005)(FRA 005)(UK005)
Day (000)
Hour (002)(001)(NZ 003)(CE
001)(C 001)(UK 001)
Decrement (001)
Access Codes
006 Installer Defined Access Codes
(4-digit decimal)
001 Installer Code (55555555)
002 Master Code (12345678)
003 Maintenance Code
(AAAAAAAA)
004 Guard Code
(AAAAAAAA)
005 - Code Version (000)
PGM Programming
007 PGM Programming
000 Main Bell Partition
Assignment
1 Partition 1
2 Partition 2
3 Partition 3
4 Partition 4
5 Partition 5
6 Partition 6
7 Partition 7
8 Partition 8
001-164 PGM 1-164 Partition
Assignment (default: partition 1)
1-8 Partition 1-8
008 PGM Timer Programming
000 PGM Timer-Minutes or
Seconds (seconds)
001-164 PGM 1-164 Timer (005)
009 PGM Types
001-164 PGM 1-164 Type
Assignment (default: PGM1=121,
PGM2=156, 3-164=101)
100 Null PGM
101 Burg and Fire Bell
Follower
102 Delayed Fire and Burg
103 Sensor Reset [*][7][2]
104 2-Wire Smoke
109 Courtesy Pulse
111 Keypad Buzzer Follow
114 Ready To Arm
115 System Armed Status
116 Away Armed Status
117 Stay Armed Status
120 Away Armed with no
Zone Bypass Status
121 Command Output 1
122 Command Output 2
123 Command Output 3
124 Command Output 4
129 Partition Status Alarm
Memory
132 Holdup Output
134 24Hr Silent Input
135 24Hr Audible Input
146 TLM and Alarm
147 Kissoff
148 Ground Start
149 Alternate
Communicator
155 System Trouble
156 Latched System Event
157 System Tamper
161 DC Trouble
165 Prox Used
166 Partition Prox Used
175 Bell Status and
Programming Access Output
176 Remote Operation
184 Open After Alarm
200 Zone Follower
201 Follower-Zones 1-8
202 Follower-Zones 9-16
203 Follower-Zones 17-24
= Default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2LCDP and is the answer not in the manual?

DSC HS2LCDP Specifications

General IconGeneral
BrandDSC
ModelHS2LCDP
CategorySecurity System
LanguageEnglish

Related product manuals