30
times. If the Auto-arm is postponed, arming or disarming
the panel will not affect the postpone sequence.
[176] - Cross Zone/Police Code Timer
This option affects the Cross Zone Police Code log and
transmission as well as the Cross Zone feature.
When a zone trip occurs, the Cross Zone Timer starts.
This timer affects the panel in two different ways
depending on the programming of the Burglary Verifica-
tion Options (Section [018], Option 6):
• If the Police Code feature is being used, the first zone
alarm will immediately transmit. If a second zone
alarm occurs in the time period (minutes) pro-
grammed in this section, the panel will log and trans-
mit the Police Code event. If the second zone alarm
occurs after this timer expires, the Police Code will not
be logged or transmitted, and the timer will restart.
• If the new Cross Zone attribute is used, the first zone
alarm will not log or transmit. If a second zone is vio-
lated within the Cross Zone Timer’s duration (sec-
onds), the panel will go into the appropriate alarm
sequence and will communicate both zone alarms. No
Police Code is sent.
NOTE:
If 000 is programmed in this section, either: the
Police Code will transmit for any two different zone alarms
during an armed-to-armed period or the new Cross Zoning
feature will not work. This is not a valid entry for Cross Zon-
ing.
NOTE:
Option[9], Section [101]-[132] must be enabled for
the Cross Zoning feature to function. Each zone has the
ability to individually protect the intended area. Cross Zon-
ing is NOT recommended for line security installations or on
exit/entry zones.
[177] - Waterflow Delay Timer
This option affects the Delayed 24-hr waterflow zone
type. The value programmed in this section is the time
for which the zone has to be violated before going into
alarm. Valid entries are from 000 to 090 seconds, with a
default of 000.
NOTE:
The total delay time (combination of control unit
plus waterflow device) for a waterflow zone alarm is not to
exceed 120 seconds.
[178] - Alarm Tone Period for Verbal Alarm
This is the period of time that the system will sound the
bell outputs before silencing them and verbally annunci-
ating the alarms through the PC5936/Escort5580(TC).
Valid entries for this section are 001-255, and the default
value is 15 seconds.
[181]-[182] - Auto-arm Schedules
Sections [181] through [182] allow the installer to program
seven independent times of the day when the selected par-
tition will arm when Auto-arm is enabled. The 7 entries
represent the days of the week as indicated below:
NOTE:
Valid entries are 0000-2359 hrs; 9999 to disable.
X = partition to which the section belongs (i.e. Section
[182] = partition two schedule). In addition to these sched-
ules, partitions can be enabled or disabled in [*][6] pro-
gramming. This is controlled by Option 2 in Section [017].
[190] - No Activity Arming Pre-Alert Duration
This is the duration for which the No Activity Arming
Pre-alert will sound when the No Activity Timer for the
partition expires (see Section [191]-[192]). If programmed
as 000, the partition will arm as soon as its No Activity
Timer expires. This feature enables the system (or parti-
tion) to arm if there is no zone activity for a programmed
time period. If the No Activity Arm
No Activity Arm No Activity Arm
No Activity Arm option for a partition
is programmed with a number other than 000, the parti-
tion will Auto-arm if no activity is detected for the pro-
grammed number of minutes.
[191]-[192] - No-Activity Timer (Partition 1-2)
The timer will begin when a delay type zone assigned to
the partition is restored. The timer is stopped if any zone
assigned to the partition is tripped or restored. The timer
will restart when a delay type zone is again restored.
When the timer expires, the panel will sound the buzzers
of all keypads assigned to the partition for the time pro-
grammed in Section [190]. If any key is pressed or zone is
violated/restored on that partition, the Auto-arm Pre-
alert will be aborted. For zone types 04, 05, 06, and 25,
restorals will not affect No Activity Arming.
. .
. A partition
begins it’s Auto-arm sequence when its No-Activity
Timer expires. If 000 is programmed in a section, No-
Activity Arming for that partition is disabled. Valid
entries are 000 - 255 minutes, with a default of 001.
The system will not arm if it is in OFF normal state.
[199] - Auto-arming Pre-Alert Time
This section allows programming of the standard Auto-
arm Pre-alert duration. If Auto-arm is postponed this
timer will re-start after the Auto-arm Postpone Timer
expires. Valid entries are from 001-255 minutes, the
default is 005.
NOTE:
There is no differentiation between the No Activity
Pre-alert and the Standard Auto-arm Pre-alert at a keypad.
No Activity Arming and Auto-arm will log and transmit as a
Special Closing.
5.5 Partition & Zone Programming
[201] Partition Selection Mask
This section allows the programming of which partitions
will be active on the system.
[202]-[213] - Partition Zone Assignments
Partitions and Zone Assignment
A partition is a limited area of the premises which will
operate independently of another area of the premises.
You can create up to 2 partitions on the PC5010 CP-01 sys-
tem.
To set up the system for more than one partition, you
must turn on each partition in section [201].
You can assign any zone to any of the partitions. Global
GlobalGlobal
Global
Zones
ZonesZones
Zones are zones assigned to more than one partition. A
global zone will only be armed when all assigned parti-
tions are armed. The zone will be disarmed when any
assigned partition is disarmed.
By default, zones 1 through 8 are assigned to partition 1.
If additional zones are being used, or if the application
requires more than one partition, you must program
which zones are assigned to which partitions. You can do
this in programming sections [202] - [213].
NOTE:
You can assign any Access Code to work on any of
the partitions (see section ’[*] [5] Programming Access
Codes’).
You can assign keypads to work on either a single parti-
tion, or on all partitions (Global operation). See Section 2
‘Keypad Assignment’.
Each partition can be programmed to report using a differ-
ent account number.
[18X] Partition X Auto-arm Times
Day Default
Sunday 9999 I___I___I___I___I
Monday 9999 I___I___I___I___I
Tuesday 9999 I___I___I___I___I
Wednesday 9999 I___I___I___I___I
Thursday 9999 I___I___I___I___I
Friday 9999 I___I___I___I___II
Saturday 9999 I___I___I___I___I
WWW.DIYALARMFORUM.COM