EasyManuals Logo
Home>DSC>Security System>SCW9045-433 v1.0

DSC SCW9045-433 v1.0 User Manual

DSC SCW9045-433 v1.0
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Section 8: Programming Descriptions
43
Section [898]: Wireless Device Enrollment - See Section 2 of this manual.
Section [899]: Template Programming - See Section 3 of this manual.
Section [900]: Panel Version Displayed
Section [900]: Display Panel Version. The system will display the version of the control panel (for example, [0100] indicates panel version 1.00).
Section [904]: Wireless Module Placement Test
Enter Section [904] followed by the 2-digit number of the wireless zone to test. When a wireless signal is received from the selected transmitter,
the system will indicate the location as Good or Bad as follows:
Press [#] to exit when testing is complete. Enter the 2-digit zone number for the next wireless device to test or press [#] to return to standard pro-
gramming.
Section [990] Installer Lockout Enable
Enter Section [990][Installer Code][990] to enable the Installer Lockout feature. A hardware default cannot be performed when the
Installer Lockout feature is ON. In addition, the system will chatter the line seizure relay 10 times if the panel is powered up to indi-
cate the feature is ON.
Section [991] Installer Lockout Disable
Enter Section [991][Installer Code][991] to turn the Installer Lockout feature OFF.
Section [996] Restore Wireless Device Default Programming
Enter Section [996][Installer Code][996] to return wireless programming to factory defaults.
Section [998] Restore Control Panel Default Programming
Enter Section [998][Installer Code][998] to return control panel programming (including 2-way Audio options, Sect [600]) to factory
defaults.
Section [999] Restore System Default Programming
Enter Section [999][Installer Code][999] to return system programming to factory defaults.
Hardware Reset (Default) Main Control Panel
Perform the following to default the main control panel:
Power down the system completely
Connect a short between I/O 1 and I/O 2 on the control panel (remove all other wires from these terminals)
Power up the control panel (AC power only) for 10 full seconds
Power down the control panel, remove short between I/O 1 and I/O 2
Power up the control panel
Good:
Bad:
One bell squawk, keypad displays ‘GOOD’
Three bell squawks, keypad displays ‘BAD’
Wireless device programming and keypad programming are not defaulted.
To default Labels see Section [996] Label Reset in Keypad Programming.
To default Wireless Devices see Section [996] above.
Except for labels, all programming including wireless device programming and keypad programming will be returned to
factory defaults. To default labels see Section [996] Label Reset in Keypad Programming.