EasyManuals Logo
Home>DSC>Security System>SCW9045-433 v1.0

DSC SCW9045-433 v1.0 User Manual

DSC SCW9045-433 v1.0
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
44
Keypad Programming
To access Keypad Programming enter [][8][Installer’s Code][].
To return to System Programming press [].
System Labels
There are 39 programmable system labels which are programmable through the Keypad or Downloading. Once a label programming section has
been entered, use the [<] and [>] Cursor keys to move left and right to get to another letter within the label. The letters of the alphabet are divided
up among the number keys 1-9 on the keypad as described below:
For example, if you press the [4] key once, the letter “J” will appear above the cursor on the display. Press the [4] key again, the next letter “K”
will appear, and so on. If a different number is pressed, e.g. the [6] key, the cursor will automatically move to the right one space, i.e. the letter
“P”. To erase a character, use the [<] [>] keys to move the cursor under the character, then press the [0] key. If the [0] key is pressed, and [<] or [>]
was the previous key pressed, the character over the cursor will be cleared. If any other key was previously pressed, then increment to and clear
the next character. While programming a label, press the [
] key to call up an options menu. To select an option, scroll through the options using
the [<] [>] keys, then press the [] key to select.
Section [001]-[034] Zone Labels
Enter a 28 character zone label for up to 32 wireless zones and 2 hardwired zones (33 & 34).
Default Value = ‘ZONE----XX’ where XX equals the zone number.
Section [065] Fire Alarm Labels
Enter a 28 character Fire Alarm label. Default Value = ‘FIRE-ZONE’.
Section [066] Fail to Arm Event Message
Enter a 32 character Fail to Arm Event Message. Default Value = ’SYSTEM HAS ------’, ‘FAILED-TO-ARM---’.
Section [067] Alarm when Armed Event Message
Enter a 32 character Alarm when Armed Event Message. Default Value = ‘ALARM-OCCURRED--’, ‘WHILE-ARMED---’.
Section [068]-[069] Command Output Label
Enter a 28 character Command Output Label label for each command Output (2 MAX).
Default Value = ‘COMMAND-O/P-X-’ where X equals the Command Output number.
[<] = Display Left (Previous)
[>] = Display Right (Next)
[1] = A B C 1
[2] = D E F 2
[3] = G H I 3
[4] = J K L 4
[5] = M N O 5
[6] = P Q R 6
[7] = S T U 7
[8] = V W X 8
[9] = Y Z 9 0
[0] = SPACE
[*] = SELECT
[#] = ESCAPE
SAVE Saves the new label.
CHANGE CASE Toggles the letter entry between upper case letters (A,B,C...) and lower case letters (a,b,c...).
ASCII ENTRY For entering uncommon characters. There are 255 characters.
Use the [<] [>] keys to scroll through the characters or enter a 3 digit number from 000-255.
Press the [*] key to enter the character into the label.
CLEAR TO END Clears the display from the character where the cursor was located to the end of the display.
CLEAR DISPLAY Clears the entire label field.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC SCW9045-433 v1.0 and is the answer not in the manual?

DSC SCW9045-433 v1.0 Specifications

General IconGeneral
BrandDSC
ModelSCW9045-433 v1.0
CategorySecurity System
LanguageEnglish

Related product manuals