SX1278 Wireless Module E32 Series User Manual
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd. 18 / 24
6. Instruction format
In sleep mode(mode 3:M1=1, M0=1), it supports below instructions on list.
(Only support 9600 and 8N1 format when setting)
No.
Instruction format
Illustration
1
C0 + working parameters
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
must be sent in succession.
( Save the parameters when power-down )
2
C1+C1+C1
Three C1 are sent in hexadecimal format. The module returns the saved parameters and
must be sent in succession.
3
C2 + working parameters
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
must be sent in succession. ( Do not save the parameters when power-down )
4
C3+C3+C3
Three C3 are sent in hexadecimal format. The module returns the version information
and they must be sent in succession.
5
C4+C4+C4
Three C4 are sent in hexadecimal format. The module will reset one time and they must
be sent in succession.
6.1 Default parameter
Default parameter valuesC0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-TTL-100
433MHz
0x0000
0x17
2.4kbps
9600
8N1
100mW
Default parameter valuesC0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-TTL-100S1
433MHz
0x0000
0x17
2.4kbps
9600
8N1
100mW
Default parameter valuesC0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-T100S2
433MHz
0x0000
0x17
2.4kbps
9600
8N1
100mW
Default parameter valuesC0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-TTL-500
433MHz
0x0000
0x17
2.4kbps
9600
8N1
500mW
Default parameter valuesC0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-TTL-1W
433MHz
0x0000
0x17
2.4kbps
9600
8N1
1W
Default parameter valuesC0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-433T30S
433MHz
0x0000
0x17
2.4kbps
9600
8N1
1W

Other manuals for Ebyte E32 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ebyte E32 Series and is the answer not in the manual?

Ebyte E32 Series Specifications

General IconGeneral
BrandEbyte
ModelE32 Series
CategoryWireless modules
LanguageEnglish

Related product manuals